FixVault

Component Testing

  1. Ignition OFF, disconnect the VES actuator harness connector.
  2. Measure for 1.6-3.1 ohms between the VES actuator terminals A and B.
    • If not within the specified range, replace the VES actuator.
  3. Measure for infinite ohms of resistance between each VES actuator terminal and the VES actuator housing.
    • If less than the specified range, replace the VES actuator.