Component Testing
- Ignition OFF, disconnect the harness at the S38 ignition mode switch.
- Place a jumper wire between ignition mode switch terminal 4 and ground.
- Place a fused jumper wire between the circuit terminals of the ignition mode switch listed below and B+:
- Ignition mode switch terminal 2
- Ignition mode switch terminal 5
- If either LED does not light, replace the S38 ignition mode switch.
- Without the button pressed, test for 4,870 Ω between the ignition mode switch terminals listed below:
- Ignition mode switch terminals 3 and 7
- Ignition mode switch terminals 4 and 6
- If not the specified value, replace the S38 ignition mode switch.
- With the button pressed, test for 1,300 Ω between the ignition mode switch terminals listed below:
- Ignition mode switch terminals 3 and 7
- Ignition mode switch terminals 4 and 6
- If not the specified value, replace the S38 ignition mode switch.