FixVault

Static Test

  1. Ignition OFF, disconnect the harness connector at the S48D Multi-Function Switch 2 - Instrument Panel.
  2. Test for infinite resistance between the signal circuit terminal 7 and the ground circuit terminal 2 with the switch in the released or open position.
    • If less than the specified value, replace the S48D Multi-Function Switch 2 - Instrument Panel.
  3. Test for less than 5 Ω between the signal circuit terminal 7 and the ground circuit terminal 2 with the switch in the pressed or closed position.