FixVault

Typical Scan Tool Data

MAP Sensor

Circuit Short to Ground Open Short to Voltage
Operating Conditions:  Engine running, transmission in Park or Neutral
Parameter Normal Range:  20-48 kPa, varies with altitude
5 V Reference 0 kPa (0 psi) 0 kPa (0 psi) 127 kPa (1.5 psi)
MAP Sensor Signal 0 kPa (0 psi) 0 kPa (0 psi) 127 kPa (1.5 psi)
Low Reference - 127 kPa (1.5 psi) -