FixVault

Circuit/System Testing

  1. Ignition OFF, disconnect the harness connector at the G21 Secondary Air Injection Pump.
  2. Ignition ON, verify that a test lamp does not illuminate between the G21 Secondary Air Injection Pump ignition voltage circuit terminal A and ground.
    • If the test lamp illuminates, test the ignition circuit for a short to voltage.
  3. If the circuit tests normal replace the Secondary Air Injection Pump Relay.