Circuit/System Testing
- Disconnect the X2 harness connector at the X50A fuse block-underhood.
- Connect a test lamp between the control circuit terminal 13 and B+.
- Command the Trunk Release ON and OFF with a scan tool. The test lamp should turn ON and OFF when changing between the commanded states.
- If the test lamp is always ON, test the control circuit for a short to ground. If the circuit tests normal, replace the K9 BCM.
- If the test lamp is always OFF, test the control circuit for a short to voltage or an open/high resistance. If the circuit tests normal, replace the K9 BCM.
- If all circuits test normal, replace the X50A fuse block-underhood.