FixVault

Circuit/System Testing

  1. Ignition OFF, disconnect the KR113 child security lock disable relay.
  2. Test for less than 10 Ω between the ground circuit terminal 1 and ground.
    • If greater than the specified range, test the ground circuit for an open/high resistance.
  3. Connect a test lamp between the control circuit terminal 3 and ground.
  4. Ignition ON, command the child security lockout by pressing the window lockout switch on the S79D driver door lock/window switch. The test lamp should turn ON and OFF when changing between the commanded states.
    • If the test lamp is always OFF, test the control circuit for a short to ground or an open/high resistance. If the circuit tests normal, replace the K9 BCM.
    • If the test lamp is always ON, test the control circuit for a short to voltage. If the circuit tests normal, replace the K9 BCM.
  5. If all circuits test normal, test or replace the KR113 child security lock disable relay.