Diagnostic Fault Information
| Circuit | Short to Ground | Open/High Resistance | Short to Voltage | Signal Performance |
|---|---|---|---|---|
| Module B+ | U2105-U2199 | U2105-U2199 | - | - |
| Module Ignition | U2105-U2199 | U2105-U2199 | - | - |
| Accessory Wakeup Serial Data | U1814 | U2105-U2199 | - | - |
| Serial Data Communication Enable | U2099 | U2105-U2199 | - | - |
| High Speed GMLAN Serial Data (+) | 2 | U2105-U2199 | 2 | - |
| High Speed GMLAN Serial Data (-) | 2 | U2105-U2199 | 2 | - |
| Low Speed GMLAN Serial Data | 1 | U2105-U2199 | 1 | - |
| Module Ground | - | U2105-U2199 | - | - |
| 1. Scan tool does not communicate with low speed GMLAN device 2. Scan tool does not communicate with high speed GMLAN device |
||||