Removal Procedure

    Fig 1: Air Cleaner Housing, Mass Air Flow Sensor Wiring Harness Plug And Mass Air Flow Sensor
    GM2191533Courtesy of GENERAL MOTORS COMPANY
  1. Disconnect the air mass sensor wiring harness plug (2) from the air mass sensor (3).
  2. Unclip the mass air flow sensor wiring harness retainer clip from the air cleaner housing (1).
  3. Fig 2: Air Cleaner Housing Air Cleaner Housing, Mass Air Flow Sensor Wiring Harness Plug And Mass Air Flow Sensor
    GM2191547Courtesy of GENERAL MOTORS COMPANY
  4. Remove the air cleaner outlet front duct clamp (3).
  5. Remove the air cleaner outlet front duct (2) from the air cleaner housing (1).
  6. Fig 3: Air Cleaner Element
    GM2191545Courtesy of GENERAL MOTORS COMPANY
  7. Remove the 5 air cleaner housing bolts (1).
  8. Remove the air cleaner upper housing (2) from the air cleaner lower housing (4).
  9. Remove the air cleaner element (3).