Approximate Fluid Capacities
Refrigerant System Capacities
| Application | Specification | |
|---|---|---|
| Metric | English | |
| Compressor Replacement | ||
|
NOTE:
The service compressor is precharged with the following amount of PAG oil. Refer to the instruction sheet included with the service compressor.Compressor failure can occur if the oil removed during refrigerant recovery is not replaced. |
40 ml1 | 1.4 oz1 |
| Condenser Replacement | 20 - 25 ml1 | 0.7 - 0.88 oz1 |
| Evaporator Replacement | 15 - 20 ml1 | 0.53 - 0.7 oz1 |
| Any Line Set (Hose/Tube or Tube Assembly) Replacement | 10 - 15 ml1 | 0.3 - 0.5 oz1 |
|
70 ml | 2.5 oz |
| Refrigerant Charge (R-134a) | ||
| Bupyeong Plant in Korea | 0.57 kg | 1.26 lb |
| SLP Plant in Mexico | - | - |
|
0.44 kg | 0.97 lb |
|
0.57 kg | 1.26 lb |
|
0.44 kg | 0.97 lb |
| 1 If more than the specified amount of PAG oil was drained from a component, add the amount drained. | ||