FixVault

Circuit/System Verification

  1. Verify a low 12V battery event did not occur. Inspect for DTC P0562 or similar. Refer to Diagnostic Trouble Code (DTC) List - Vehicle .
    • Go to next step: If a low 12V battery condition did not occur 
  2. Record the freeze frame/failure records for DTC P0C76.
  3. Perform the High Voltage Disabling procedure and test for high voltage present.
    • Go to next step: If a high voltage present condition was not observed 
  4. Review the DTC P0C76 Freeze Frame/Failure Records. Verify if the Drive Motor Inverter Supply Voltage Circuit Parameter was 86V or less.
    • If the parameter is greater than 86V 

      Replace the component: A28 Hybrid/EV Battery Contactor Assembly

    • Go to next step: If the parameter is 86V or less 
  5. Replace the component: K59 Starter/Generator Control Module.