FixVault

Unit Alignment

CAUTION: Do not allow fingers or clothing to come in contact with cycling mechanism as personal injury or mechanical damage may result.
  1. Lateral lock adjustment is provided by slotted holes in lid inner panel. Vertical adjustment is provided by slotted holes in latch unit. Lid must be properly aligned on body before latch system is adjusted.
  2. Disconnect motor power wire connector. Use a screwdriver to turn secondary gear output shaft and manually cycle unit counterclockwise in direction of arrow on unit to full down position. Set output cam against lock release lever (anti-reversing stop).
  3. Loosen bolts on unit cover, then adjust striker for proper weatherstrip compression and lid fit to adjacent panels. Connect motor power wire.
    NOTE: When power wire is connected, and plunger is in contact with striker, unit will cycle to full up position.