FixVault

Sequential Fuel Injection

In sequential fuel injection, each injector is energized independently and in engine firing order. Injector pulses are controlled by ECM and are based on an ignition reference pulse from distributor. Injection timing remains fixed, at base engine timing, throughout engine speed range.

In order to properly control fuel supply, fuel pump is operated by ECM through fuel pump relay and oil pressure switch.