EXPERTEC Technical Service Bulletins (T88-25)
Publication date: 1987-09-17Reference number: T88-25
EXPERTEC TECHNICAL SERVICE BULLETINS
TECHNICAL SERVICE BULLETIN
CODE F41 OR B441 COOLING FAN FAULT INTERMITTENTLY
Model(s): 1985-87 Cadillac DeVille & Fleetwood
1986-87 Cadillac Eldorado & Seville
1987 Cadillac Allante
Bulletin No.: T88-25
Date: September 17, 1987
SERVICE INFORMATION
Some 1985-1987 DeVilles and Fleetwoods may have a condition of an intermittent cooling fan fault light on and a code F41.
Some 1986-1987 Eldorados, Sevilles and Allantes may have a condition of an intermittent "Cooling Fan Fault" message on the CCDIC and a code B441.
If these conditions occur, and the diagnostic tree in the Service Manual does not lead to the cause of this condition, use the following diagnosis.
DIAGNOSIS
Step 1 - Check for the proper fan control module. 1985 DeVilles and Fleetwoods should have a fan module with part number 1632916 imprinted on the black plastic portion of the case. All 1986 and 1987 vehicles should have a fan module part number 1638574 or 1641400.
Step 2 - Check the fan control module ground connection near the starter. A loose or dirty ground connection near the starter may cause a false code F41 or B441 to set.
Step 3 - Check the cooling fan motors for excessive amperage draw. Disconnect the cooling fan module signal connector (circuits 790 and 791). Using an in-line or inductive ammeter with a 50 amp or lower full scale reading, measure the amperage draw of each fan motor while the fans are overridden at full speed. Use of an ammeter with a 50 amp or lower full scale reading will help ensure a reliable amperage reading. Consult the table below to determine if a cooling fan motor is drawing excessive current:
| Year | Car Line | Small Cooling Fan | Large Cooling Fan |
|---|---|---|---|
| 1985 | DeVille & Fleetwood | 13 Amps | 13 Amps |
| 1986 | DeVille, Fleetwood, Eldorado & Seville | 13 Amps | 13 Amps |
| 1987 | DeVille & Fleetwood | 8 Amps | 14.5 Amps |
| 1987 | Eldorado, Seville & Allante | 13 Amps | 13 Amps |
If a cooling fan is found to exceed the maximum acceptable cooling fan draw, it should be replaced.
WARRANTY INFORMATION
For warranty purposes, use:
Labor Operation No.: J3400
Labor Time: 0.3 hour for one fan
0.4 hour for both fans on DeVilles
0.6 hour for both fans on Eldorados & Sevilles