Notes On Intermittents

Manipulate wiring on circuits No. 410PC and 476PC, coolant sensor, and ECM connector while observing ECM parameter ED04. If failure is induced, coolant temperature will jump from its normal value to the open reading of -35°C or less.

Disconnect and reconnect both the coolant sensor and ECM connectors, and ensure that they are properly latched. If wiring and connectors are okay, substitute and known good sensor and retest. Review snapshot data parameters stored with this code to verify failure. If failure is verified, check and repair intermittent wiring connection or sensor.

Fig 1: ECM Code E015, Open Coolant Sensor Circuit Schematic
G57303
Fig 2: Flow Chart, Code E015, Open Coolant Sensor Circuit
G111788