Installation Procedure
CAUTION:
When you are carrying an undeployed inflator module:
- Do not carry the inflator module by the wires or connector on the inflator module
- Make sure the bag opening points away from you
- Install the module
- Connect the module electrical connectorNOTE: Use the correct fastener in the correct location. Replacement fasteners must be the correct part number for that application. Fasteners requiring replacement or fasteners requiring the use of thread locking compound or sealant are identified in the service procedure. Do not use paints, lubricants, or corrosion inhibitors on fasteners or fastener joint surfaces unless specified. These coatings affect fastener torque and joint clamping force and may damage the fastener. Use the correct tightening sequence and specifications when installing fasteners in order to avoid damage to parts and systems
- Install the Torx® screws. Tighten the screws to 8 N.m (72 lb in).
- Enable the SIR system. Refer to DISABLING & ACTIVATING AIR BAG SYSTEM