FixVault

Removal Procedure

  1. Remove the instrument panel (I/P) cluster bezel. Refer to BEZEL REPLACEMENT - INSTRUMENT PANEL (I/P) CLUSTER in Instrument Panel, Gages, and Console.
  2. Using a flat-tipped screwdriver, gently pry the retaining clips open on the housing.
  3. Slide out the selector switch until the electrical connectors are accessible.
  4. Disconnect the selector switch electrical connectors (2, 3).
    Fig 1: Disconnecting Selector Switch Electrical Connectors
    G01456663Courtesy of GENERAL MOTORS CORP.
  5. Remove the selector switch from the housing.
    Fig 2: Removing Selector Switch From Housing
    G01456664Courtesy of GENERAL MOTORS CORP.