Installation Procedure
- Clean out all traces of dirt and other contaminants from the air cleaner base and lid.
- Place the air cleaner element between the assembly halves with the 2 locating tabs positioned down.
- Join the 2 air cleaner assembly halves.
- Tighten the 2 air cleaner element screws.
Tighten: Tighten the air cleaner element screws to 8 N.m (71 lb in).
IMPORTANT:
Ensure that the air cleaner assembly halves are properly fitted to each other.
NOTE:
Refer to Fastener Notice
in Cautions and Notices.