Installation Procedure
- Install the surge tank.
- Install the bolt to the surge tank.
Tighten: Tighten the bolt to 9 N.m (80 lb in).
- Install the nut to the surge tank.
Tighten: Tighten the nut to 9 N.m (80 lb in).
- Install the surge tank outlet hose (2) to the surge tank.
- Position the surge tank outlet hose clamp.
- Install the surge tank inlet hose (1) to the surge tank.
- Position the surge tank inlet hose clamp.
- Connect the low coolant level switch electrical connector (3).
- Install the surge tank overflow hose.
- Install the air cleaner assembly. Refer to Air Cleaner Assembly Replacement in Engine Controls - 4.8L, 5.3L, and 6.0L or Air Cleaner Assembly Replacement in Engine Controls - 8.1L.
- Fill the cooling system. Refer to Draining and Filling Cooling System .
NOTE:
Refer to Fastener Notice
in Cautions and Notices.