FixVault

Scan Tool Data List

Body Control Module Scan Tool Data List

Scan Tool Parameter Data List Units Displayed Typical Data Value
RUN MODE ON
Battery Voltage Signal Data Volts 9-16 Volts
LF Door Ajar Switch Data Door Closed/Ajar Door Closed
LF Latch Solenoid Command Data Active/Inactive Inactive
RF Door Ajar Switch Data Door Closed/Ajar Door Closed
RF Latch Solenoid Command Data Active/Inactive Inactive
Driver Door Module Scan Tool Data List

Scan Tool Parameter Data List Units Displayed Typical Data Value
RUN MODE ON
Battery Voltage Signal Data Volts 9-16 Volts
Driver Mirror Fold Motor Command Data Idle/Extend/Retract Idle
Driver Mirror Heater Data Active/Inactive Inactive
Driver Mirror Motors Command Data Idle/Up/Down/Left/Right/Left Up/Left Down/Right Up/Right Down Idle
Driver Mirror Horizontal Position Data Counts 25-225 Counts
Driver Mirror Horizontal Position Data Volts 0.5-4.5 Volts
Driver Mirror Vertical Position Data Counts 25-225 Counts
Driver Mirror Vertical Position Data Volts 0.5-4.5 Volts
Driver Window Motor Command Data Idle/Up/Down Idle
Driver Window Position Data Counts Varies
Ext. Driver Door Handle Switch Data Active/Inactive Inactive
Hall Sensor 1 Data Active/Inactive Inactive
Hall Sensor 2 Data Active/Inactive Inactive
Int. Driver Door Handle Switch Data Active/Inactive Inactive
Lock Switch Indicator Command Data Active/Inactive Inactive
Memory 1 Mirror Horizontal Value Data Counts 25-225 Counts
Memory 1 Mirror Horizontal Value Data Volts 0.5-4.5 Volts
Memory 1 Mirror Vertical Value Data Counts 25-225 Counts
Memory 1 Mirror Vertical Value Data Volts 0.5-4.5 Volts
Memory 2 Mirror Horizontal Value Data Counts 25-225 Counts
Memory 2 Mirror Horizontal Value Data Volts 0.5-4.5 Volts
Memory 2 Mirror Vertical Value Data Counts 25-225 Counts
Memory 2 Mirror Vertical Value Data Volts 0.5-4.5 Volts
Window Normalization Data Yes/No Yes
Driver Door Switch Scan Tool Data List

Scan Tool Parameter Data List Units Displayed Typical Data Value
RUN MODE ON
Battery Voltage Signal Data Volts 9-16 Volts
Door Lock Switch Data Idle/Lock/Unlock Idle
Drvr. LF Window Switch Data Idle/Up/Down/Express Up/Express Down Idle
Drvr. RF Window Switch Data Idle/Up/Down/Express Up/Express Down Idle
Mirror Direction Switch Data Idle/Up/Down/Left/Right/Left Up/Left Down/Right Up/Right Down Idle
Mirror Fold Switch Data Idle/Extend/Retract Idle
Mirror Select Switch Data Off/Driver/Passenger Off
Window Lockout Switch Data On/Off Off
Window Lockout Switch Indicator Command Data Active/Inactive Inactive
Passenger Door Module Scan Tool Data List

Scan Tool Parameter Data List Units Displayed Typical Data Value
RUN MODE ON
Battery Voltage Signal Data Volts 9-16 Volts
Ext. Psgr. Door Handle Switch Data Active/Inactive Inactive
Front Psgr. Window Motor Command Data Idle/Up/Down Idle
Front Psgr. Window Position Data Counts Varies
Front Psgr. Window Switch Data Idle/Up/Down/Express Up/Express Down Idle
Hall Sensor 1 Data Active/Inactive Inactive
Hall Sensor 2 Data Active/Inactive Inactive
Int. Psgr. Door Handle Switch Data Active/Inactive Inactive
Lock Switch Indicator Command Data Active/Inactive Inactive
Memory 1 Mirror Horizontal Value Data Counts 25-225 Counts
Memory 1 Mirror Horizontal Value Data Volts 0.5-4.5 Volts
Memory 1 Mirror Vertical Value Data Counts 25-225 Counts
Memory 1 Mirror Vertical Value Data Volts 0.5-4.5 Volts
Memory 2 Mirror Horizontal Value Data Counts 25-225 Counts
Memory 2 Mirror Horizontal Value Data Volts 0.5-4.5 Volts
Memory 2 Mirror Vertical Value Data Counts 25-225 Counts
Memory 2 Mirror Vertical Value Data Volts 0.5-4.5 Volts
Psgr. Mirror Fold Motor Command Data Idle/Extend/Retract Idle
Psgr. Mirror Heater Data Active/Inactive Inactive
Psgr. Mirror Horizontal Position Data Counts 25-225 Counts
Psgr. Mirror Horizontal Position Data Volts 0.5-4.5 Volts
Psgr. Mirror Motors Command Data Idle/Up/Down/Left/Right/Left Up/Left Down/Right Up/Right Down Idle
Psgr. Mirror Vertical Position Data Counts 25-225 Counts
Psgr. Mirror Vertical Position Data Volts 0.5-4.5 Volts
Window Normalization Data Yes/No Yes