Installation Procedure
CAUTION:
Refer to Gasoline/Gasoline Vapors Caution
in Cautions and Notices.
NOTE:
Clean all of the following areas before performing any disconnections in order to avoid possible contamination in the system:
- The fuel pipe connections
- The hose connections
- The areas surrounding the connections
- Relieve the fuel pressure. Refer to Fuel Pressure Relief Procedure .
- Remove the fuel pressure test port cap.
- Install the fuel pressure gage to the fuel pressure test port.
- Place the shop towel in an approved container.
- Perform any tests and/or diagnostics as needed.
CAUTION:
Wrap a shop towel around the fuel pressure connection in order to reduce the risk of fire and personal injury. The towel will absorb any fuel leakage that occurs during the connection of the fuel pressure gage. Place the towel in an approved container when the connection of the fuel pressure gage is complete.