FixVault

Installation Procedure

    Fig 1: MAP, IAC, ECT, TP Sensors Component View
    GM602335Courtesy of GENERAL MOTORS CORP.
  1. Install the MAP (1) sensor into the intake manifold.
  2. NOTE: Refer to Fastener Notice in Cautions and Notices.
  3. Install the accelerator control cable bracket and bolts.

    Tighten:  Tighten the bracket bolts to 12 N.m (106 lb. in.).

  4. Connect the MAP sensor electrical connector.