NOTE: Replacement components must be the correct part number for the application. Components requiring the use of the thread locking compound, lubricants, corrosion inhibitors, or sealants are identified in the service procedure. Some replacement components may come with these coatings already applied. Do not use these coatings on components unless specified. These coatings can affect the final torque, which may affect the operation of the component. Use the correct torque specification when installing components in order to avoid damage.
NOTE: Use care when handling the coolant sensor. Damage to the coolant sensor will affect the operation of the fuel control system.
    Fig 1: View Of ECT Sensor
    GM855737Courtesy of GENERAL MOTORS CORP.
    NOTE: Refer to Fastener Notice in Cautions and Notices.
  1. If installing the old sensor, coat the threads with sealant GM P/N 12346004 (Canadian P/N 10953480) or equivalent.
  2. Install the ECT sensor.

    Tighten:  Tighten the sensor to 20 N.m (15 lb ft).

  3. Fig 2: View Of Engine Wiring Harness Ground Bolt, ECT Sensor Electrical Connector, Negative Battery Cable & Harness Ground (4.8L, 5.3L, and 6.0L Engines)
    GM1235684Courtesy of GENERAL MOTORS CORP.
  4. Connect the ECT sensor electrical connector (5).
  5. Refill the cooling. Refer to Draining and Filling Cooling System in Engine Cooling.