Circuit Description
The heated oxygen sensor (HO2S) produces a voltage that varies between 100-900 mV under normal operating conditions. The engine control module (ECM) produces a bias voltage on the HO2S signal circuit of 420-480 mV. The reference ground for the sensor is provided through the ECM. The ECM monitors the signal voltage to determine if the exhaust is lean or rich. The oxygen sensor voltage is high when the exhaust is rich, and low when the exhaust is lean. The ECM constantly monitors the HO2S signal during the Closed Loop operation. If the ECM detects that the HO2S internal resistance remains above a specified threshold for longer than a predetermined amount of time, DTC P0141 will set for bank 1 sensor 2, or DTC P0161 will set for bank 2 sensor 2.