FixVault

Circuit Description

An ignition voltage is supplied directly to the evaporative emission (EVAP) canister purge solenoid valve. The EVAP canister purge solenoid valve is pulse width modulated (PWM). The scan tool displays the amount of ON time as a percentage. The control module controls the EVAP canister purge solenoid valve ON time by grounding the control circuit via an internal switch called a driver. The control module monitors the status of the driver. If the control module detects an open circuit on the control circuit while the driver is commanded OFF, this DTC sets.