Circuit Description
An ignition voltage is supplied directly to the evaporative emission (EVAP) canister purge valve. The EVAP canister purge valve is pulse width modulated (PWM). The scan tool displays the amount of ON time as a percentage. The control module monitors the status of the driver. The control module controls the EVAP canister purge solenoid valve ON time by grounding the control circuit via an internal switch called a driver. If the control module detects voltage on the control circuit when the driver is commanded ON, this DTC sets.