FixVault

Removal Procedure

    Fig 1: Blowing Dirt Out Of Fitting (Plastic Collar)
    GM155410Courtesy of GENERAL MOTORS CORP.
  1. Relieve the fuel system pressure before servicing any fuel system connection. Refer to the Fuel Pressure Relief Procedure .
  2. CAUTION: Wear safety glasses when using compressed air in order to prevent eye injury.
  3. Using compressed air, blow any dirt out of the quick-connect fitting.
  4. Fig 2: Squeezing Quick Connect Fitting Release Tabs (Plastic Collar)
    GM12777Courtesy of GENERAL MOTORS CORP.
    IMPORTANT: Plastic quick connect fittings can be released either by squeezing the plastic retainer release tabs (step 3) or by using the appropriate J 37088-A  Fuel Line Quick Connect Separator Tool (step 4). See Special Tools .
  5. Squeeze the plastic retainer release tabs.
  6. Fig 3: Releasing Quick Connect Locking Tabs (Metal Collar)
    GM12780Courtesy of GENERAL MOTORS CORP.
  7. Choose the correct tool from the J 37088-A  Tool Set for the size of the fitting. See Special Tools . Insert the tool into the female connector, then push inward in order to release the locking tabs. The plastic retainer will remain on the female connector.
  8. Fig 4: Pulling Connection Apart (Plastic Collar)
    GM12778Courtesy of GENERAL MOTORS CORP.
  9. Pull the connection apart.