Fastener Tightening Specifications (Unit Repair)
Fastener Tightening Specifications
| Description of Usage | Ref No.* | Qty | Size | Specification | |
|---|---|---|---|---|---|
| Metric | English | ||||
| Accumulator Housing to Valve Body | 318 | 12 | M6x1.0x30.0 | 11 N.m | 97 lb in |
| Channel Plate to Valve Body | 300 | 7 | M6x1.0x38.0 | 11 N.m | 97 lb in |
| Converter Housing to Case | 2 | 7 | M8x1.25x35.0 | 22 N.m | 16 lb ft |
| Drain Plug to Fluid Pan | 63 | 1 | M14x1.5x10.0 | 20 N.m | 15 lb ft |
| Extension Housing to Case | 35 | 7 | M8x1.25x35.0 | 22 N.m | 16 lb ft |
| Fluid Pan to Case | 65 | 20 | M6x1.0x16.0 | 11 N.m | 97 lb in |
| Front Control Valve Body to Top Channel Plate | 50 | 2 | M6x1.0x38.0 | 11 N.m | 97 lb in |
| Input Speed Sensor to Case | 45 | 1 | M6x1.0x20.0 | 11 N.m | 97 lb in |
| Output Speed Sensor to Case | 43 | 1 | M6x1.0x30.0 | 11 N.m | 97 lb in |
| Parking Pawl Actuator Bracket to Case | 609 | 2 | M8x1.25x25.0 | 22 N.m | 16 lb ft |
| Prop Shaft Flange to Output Shaft | 34 | 1 | M22x1.5x10.0 | 57 N.m | 42 lb ft |
| Torque Converter Housing Seal Bolt | 228 | 2 | M4x0.7x10.0 | 3.6 N.m | 31.86 lb in |
| Transmission Fluid Pump Cover to Torque Converter Housing | 240 | 6 | M6x1.0x40.0 | 11 N.m | 97 lb in |
| Transmission Fluid Pump Cover to Torque Converter Housing | 241 | 5 | M8x1.25x40.0 | 22 N.m | 16 lb ft |
| Transmission Level Hole Plug to Case | 36 | 1 | M18x1.5x12.0 | 20 N.m | 15 lb ft |
| Transmission Pressure Test Plug to Case | 40 | 1 | M10x1.0x8.0 | 11 N.m | 97 lb in |
| Valve Body to Case | 49 | 2 | M6x1.0x50.0 | 11 N.m | 97 lb in |
| Valve Body to Case | 51 | 6 | M6x1.0x50.0 | 11 N.m | 97 lb in |
| Valve Body to Case | 53 | 1 | M6x1.0x68.0 | 11 N.m | 97 lb in |
| Valve Body to Channel Plate | 53 | 1 | M6x1.0x68.0 | 11 N.m | 97 lb in |
| * Reference Number refers to the callout number on the disassembled view. | |||||