Typical Scan Tool Data

SC Inlet Pressure Sensor

Circuit Short to Ground Open Short to Voltage
Operating Conditions:  Ignition ON, engine OFF
Normal Parameter Range:  Varies 30-125 kPa
5-Volt Reference 8-10 kPa 8-10 kPa 100-210 kPa
SCIP Sensor Signal 8-10 kPa 8-10 kPa 100-210 kPa
Low Reference - 90-107 kPa -
BARO Sensor

Circuit Short to Ground Open Short to Voltage
Operating Conditions:  Ignition ON, engine OFF
Normal Parameter Range  BARO-Refer to Altitude Versus Barometric Pressure
5-Volt Reference Circuit 8-10 kPa 8-10 kPa 200-208 kPa
Sensor Signal Circuit 8-10 kPa 8-10 kPa 200-208 kPa
Low Reference - 191 kPa -