FixVault

Typical Scan Tool Data

IAT Sensor 2

Circuit Normal Range Short to Ground Open or High Resistance Short to Voltage
IAT Sensor 2 Signal 1 Varies 140°C (284°F) -40°C (-40°F) -40°C (-40°F)
IAT Sensor 2 Low Reference - - -40°C (-40°F) -40°C (-40°F)
1 Varies -39 to +120°C (-38 to +248°F)