FixVault

Component Testing

  1. Ignition OFF, disconnect the top vacuum hose at the bypass actuator.
  2. Connect a vacuum gage to the actuator. Apply 10 in Hg to the actuator. The actuator should retract and hold vacuum for at least 15 seconds.
    • If the actuator does not hold vacuum, replace the actuator.