  1. Ignition OFF, disconnect the harness connector at the EBCM.
  2. Test for less than 1.0 ohm of resistance from ground circuit terminal 26 (LE5) or 18 (LNF) and ground.
    • If greater than the specified range, test the ground circuit for an open/high resistance.
  3. Test for less than 1.0 ohm of resistance from ground circuit terminal 13 and ground.
    • If greater than the specified range, test the ground circuit for an open/high resistance.
  4. Ignition ON, verify that a test lamp illuminates between the B+ circuit terminal 1(LNF) or 14 (LE5) and ground.
    • If the test lamp does not illuminate, test the B+ circuit for a short to ground or an open/high resistance.
  5. Verify that a test lamp illuminates between the B+ circuit terminal 32 (LNF) or 1(LE5) and ground.
    • If the test lamp does not illuminate, test the B+ circuit for a short to ground or an open/high resistance.
  6. If all circuits test normal, test or replace the EBCM assembly.