Component Testing
- Ignition OFF, disconnect the VES actuator harness connector.
- Measure for 5-10 ohms of resistance between the VES actuator terminals A and B.
- If the resistance is outside the specified range, replace the VES actuator.
- Measure for infinite ohms of resistance between each VES actuator terminal and the VES actuator housing.
- If less than the specified range, replace the VES actuator.