FixVault

Dynamic Test

  1. Install a 3A fused jumper wire between the ignition supply circuit terminal and 12 volts. Install a jumper wire between the control terminal and ground.
  2. Toggle the jumper wire between the control terminal and ground.
  3. Feel and listen for the operation of the SCB solenoid.
    • If the function does not perform as specified, replace the SCB solenoid.