FixVault

Circuit/System Testing

  1. Ignition OFF, disconnect the harness connector at the appropriate door module.
  2. Ignition ON, test for 9.6-13.6 volts between the B+ circuit terminal 20 and ground.
    • If less than the specified range, test the B+ circuit for a an open/high resistance. If the circuit tests normal, replace the door module.
    • If the circuit tests normal and the system voltage is less than or greater than the specified range, refer to Charging System Test .