Installation Procedure

    Fig 1: CMP Sensor
    GM1672561Courtesy of GENERAL MOTORS CORP.
  1. Lubricate the CMP sensor O-ring seal with clean engine oil.
  2. Install the CMP sensor.
  3. CAUTION: Refer to Fastener Caution .
  4. Install the CMP sensor bolt.

    Tighten:  Tighten the bolt to 10 N.m (89 lb in).

  5. Fig 2: Identifying CMP Sensor Wiring Harness Connector
    GM1672927Courtesy of GENERAL MOTORS CORP.
  6. Connect the electrical connector (1) to the CMP sensor.