Circuit/System Testing

  1. Ignition OFF, disconnect the harness connector at the intrusion sensor.
  2. Ignition ON, verify a test lamp illuminates between the B+ circuit terminal A and ground.
    • If the test lamp does not illuminate, test the B+ circuit for a short to ground or an open/high resistance.
  3. Ignition OFF, disconnect the X2 harness connector at the RIM.
  4. Ignition ON, test for less than 1 volt between the following signal circuit terminals and ground:
    • Signal circuit terminal 11
    • Signal circuit terminal 20
    • If greater than the specified range, test the signal circuit for a short to ground.
  5. Test for infinite resistance between the following signal circuit terminals and ground:
    • Signal circuit terminal 11
    • Signal circuit terminal 20
    • If less than the specified value, test the signal circuit for a short to ground.
  6. Test for less than 2 ohms between the signal circuit terminal 11 at the RIM and the signal circuit terminal C at the inclination sensor.
    • If greater than the specified range, test the signal circuit for an open/high resistance.
  7. Test for less than 2 ohms between the signal circuit terminal 20 at the RIM and the signal circuit terminal B at the inclination sensor.
    • If greater than the specified range, test the signal circuit for an open/high resistance.
  8. If all circuits test normal, test or replace the intrusion sensor.