Diagnostic Aids
- Use the DTC Descriptor list above to determine the module which is not communicating.
- If there are multiple non-communicating modules choose the one closest to the SCM.
- Possible causes of this DTC are as follows:
- Inspect the mounting of the Yaw sensor to ensure proper orientation and installation of the sensor.
- On a level surface, read the Yaw sensor offset value to ensure a value within the proper range.