Circuit/System Testing
- Ignition ON, verify the scan tool Driver Door Switch Memory Recall Switches parameter is approximately 2.75 volts while pressing the memory 1 switch.
- If not the specified value, perform the Memory Switch component test. If the switch tests normal, replace the driver door module.
- Verify the scan tool Memory Recall Switches parameter is approximately 1.75 volts while pressing the memory 2 switch.
- If not the specified value, replace the memory seat adjuster switch.
- Verify the scan tool Memory Recall Switch parameter is approximately 1.0 volt while pressing the EXIT switch.
- If not the specified value, replace the memory seat adjuster switch.
- If all circuits test normal, replace the MSM.