Circuit/System Testing
ASC Disable Switch Circuit Test
- Ignition OFF, disconnect the harness connector at the IP multifunction switch.
- Test for less than 10 ohms between the listed ground circuit terminal and ground.
- X88/Z88 Terminal 3
- Z75 terminal 1
- If greater than the specified range, test the ground circuit for an open/high resistance.
- Ignition ON, verify the scan tool ASC Disable Switch parameter is Inactive.
- If not the specified value, test the signal circuit terminal 9 for a short to ground. If the circuit tests normal, replace the ASC module.
- Install a 3A fused jumper wire between the signal circuit terminal 9 and ground. Verify the scan tool ASC Disable Switch parameter is Active.
- If not the specified value, test the signal circuit for a short to voltage or an open/high resistance. If the circuit tests normal, replace the ASC module.
- If all circuits test normal, test or replace the IP multifunction switch.
ASC Actuator Circuit Test
- Ignition OFF, disconnect the harness connector at the appropriate actuator.
- Scan tool disconnected, test for less than 20 ohms between the low reference circuit terminal C and ground.
- If greater than the specified range, test the low reference circuit for an open/high resistance. If the circuit tests normal, replace the ASC module.
- Ignition ON, command the appropriate actuator with a scan tool while using the DMM Min/Max function to capture voltage. Test for greater than 9 volts between the 10-volt reference circuit terminal D and ground.
- If less than the specified range, test the 10-volt reference circuit for a short to ground or an open/high resistance. If the circuit tests normal, replace the ASC module.
- Command the appropriate actuator with a scan tool while using the DMM Min/Max function to capture voltage. Test for greater than 9 volts between the signal circuit terminal E and ground.
- If less than the specified range, test the signal circuit for a short to ground or an open/high resistance. If the circuit tests normal, replace the ASC module.
- Using a scan tool, command the appropriate actuator both directions while using the DMM Min/Max function to capture voltage. Test for greater than 2 volts between the control circuit terminal A and ground.
- If less than the specified range, test the control circuit for a short to ground or an open/high resistance. If the circuit tests normal, replace the ASC module.
- Using a scan tool, command the appropriate actuator both directions while using the DMM Min/Max function to capture voltage. Test for greater than 2 volts between the control circuit terminal B and ground.
- If less than the specified range, test the control circuit for a short to ground or an open/high resistance. If the circuit tests normal, replace the ASC module.
- If all circuits test normal, replace the ASC actuator.