FixVault

Typical Scan Tool Data

Battery Current - BCM

Circuit Short to Ground Open Short to Voltage
Operating Conditions:  Ignition ON, engine OFF. Headlamps and all accessories Off.
Parameter Normal Range:  -5A to -25A
BCM B+ -59.9A -59.9A -
5-Volt Reference -59.9A -59.9A -
Signal -59.9A 59.9A 59.9A
Low Reference - 59.9A -
Battery Voltage - BCM

Circuit Short to Ground Open Short to Voltage
Operating Conditions:  Ignition ON, engine OFF.
Parameter Normal Value:  12.60V
BCM B+ 25.60V 26.10V -