FixVault

Circuit/System Testing

  1. Ignition OFF, disconnect the harness connector at the DIC switch assembly.
  2. Ignition OFF, test for less than 1 ohm between the low reference terminal 2 and ground.
    • If greater than the specified range, test the low reference circuit for an open/high resistance.
  3. Ignition OFF, test for less than 5 ohms between the ground circuit terminal 5 and ground.
    • If greater than the specified range, test the ground circuit for an open/high resistance.
  4. Ignition ON, verify that all of the scan tool DIC Switch parameters are Inactive.
    • If any are not Inactive, test the signal circuit terminal listed below for a short to ground. If the circuit tests normal, replace the IPC.
    • DIC Switch Signal Terminal 1
    • DIC Select Switch Signal Terminal 3
  5. Ignition ON, install a 3A fused jumper wire between the signal circuit terminal 1 and the low reference circuit terminal 2. Verify the scan tool DIC Switch parameters, except the DIC Fuel Info. parameter, are Active.
    • If any are not Active, test the signal circuit for a short to voltage or an open/high resistance. If the circuit tests normal, replace the IPC.
  6. Ignition ON, install a 3A fused jumper wire between the signal circuit terminal 3 and ground. Verify the scan tool DIC Fuel Info. parameter is Active.
    • If not Active, test the signal circuit for a short to voltage or and open/high resistance. If the circuit tests normal, replace the IPC.
  7. If all the circuits test normal, test or replace the DIC switch assembly.