FixVault

Installation Procedure

  1. Install a NEW exhaust gasket to the turbocharger and position the catalytic converter to the engine.
  2. Fig 1: Catalytic Converter Nuts
    GM3284064Courtesy of GENERAL MOTORS COMPANY
    CAUTION:

    Refer to Fastener Caution .

  3. Install NEW exhaust manifold studs (2) and tighten to 25 (18 lb ft).
  4. Install NEW catalytic converter nuts (1) and tighten to 50 (37 lb ft) .
  5. Fig 2: Catalytic Converter Heat Shield
    GM3284059Courtesy of GENERAL MOTORS COMPANY
  6. Install the catalytic converter heat shield (2) and tighten the fasteners (1) to 10 (89 lb in) .
  7. Fig 3: Catalytic Converter Bracket
    GM3284055Courtesy of GENERAL MOTORS COMPANY
  8. Install the transmission fastener (1) and tighten to 58 (43 lb ft).
  9. Install the exhaust front pipe. Refer to Exhaust Front Pipe Replacement (LF3) .
  10. Install the heated oxygen sensor. Refer to Heated Oxygen Sensor Replacement - Bank 1 Sensor 1 (LF3) .
  11. Install the turbocharger wastegate actuator vacuum tank. Refer to Turbocharger Wastegate Actuator Vacuum Tank Replacement (LF3) .
  12. Start the engine and check for exhaust leaks.