Removal Procedure
- Disable the high voltage system. High Voltage Disabling
- Drain the power electronics and auxiliary radiator cooling system. Power Electronics and Auxiliary Radiator Drain and Fill (LTG HP9)
Air Cleaner Assembly (2) - Remove - Air Cleaner Assembly Replacement
Retainer (1)@Drive Motor Generator Control Module Coolant Pump Hose (2) - Disengage
- Drive Motor Generator Control Module Coolant Pump Hose (2)@Generator Control Module Coolant/Air Separator - Remove
Radiator Inlet Hose Clip (1)@Drive Motor Generator Control Module Coolant Pump Hose (2) - Remove
Drive Motor Generator Control Module Coolant Pump Hose Bolt (1)@Drive Motor Generator Control Module Coolant Pump Hose (2) - Remove
Drive Motor Generator Control Module Coolant Pump Hose Clamp (1) - Disengage - Hose Clamp Replacement Guidelines - Spring Type
- Drive Motor Generator Control Module Coolant Pump Hose (2)@Generator Control Module Coolant Pump - Remove
- Drive Motor Generator Control Module Coolant Pump Hose (2) - Remove