Circuit/System Verification
- Ignition - On/Vehicle - In Service Mode
- Verify the scan tool parameter:
Battery Charger Coupler Lock Command & Battery Charger Coupler Lock display the same state.
- If not the specified state
Refer to: Circuit/System Testing
- Go to next step: If the specified state
- If not the specified state
- Verify the scan tool parameter: Battery Charger Coupler Lock Command & Battery Charger Coupler Lock = The parameter value should not change
Perform the action while monitoring the parameter:
- Wiggle the harness and connector(s):X2 @ X98 Battery Charger Coupler
- Wiggle the harness and connector(s):X2 @ K16 Battery Energy Control Module
- If the parameter value changes
Repair as necessary - Wiring/Terminal(s)/Electrical Connector(s)
- Go to next step: If the parameter value does not change
- Operate the vehicle within the Conditions for Running the DTC. You may also operate the vehicle within the conditions that you observed from the Freeze Frame/Failure Records data.
Verify that no DTCs are set.
- If any of the DTCs are set
Refer to: Circuit/System Testing
- Go to next step: If none of the DTCs are set
- If any of the DTCs are set
- All OK.