Two brushes carry current through the slip rings to the field coil mounted on the rotor. The stator windings are assembled on the inside of a laminated core that forms part of the alternator frame. A rectifier bridge connected to the stator windings contains 6 diodes (3 positive and 3 negative) molded into an assembly. The rectifier bridge changes stator A.C. voltage into D.C. voltage, which appears at the output "BAT" terminal.
The blocking action of the diodes prevents battery discharge back through the alternator. Because of this blocking action, need for a cutout relay is eliminated. The alternator field current is supplied through a diode trio, which is also connected to the stator windings. A capacitor is mounted in the end frame to protect the rectifier bridge and diodes from high voltage and to suppress radio noise.