FixVault

Float Level

NOTE: Remove needle valve wire clip and install new inlet seat gasket before adjusting float.
  1. Remove air horn gasket, invert air horn and allow float to hang by its own weight. Measure clearance between top of float and air horn. See Fig 1 .
  2. Clearance should be .275" (7.0 mm). Adjust clearance by bending float arm at tab "A". See Fig 2 .
Fig 1: Float Level Measurement
G5154
Fig 2: Float Level Adjustment Adjust gap by bending float arm at tab "A".