Float Level
NOTE:
Remove needle valve wire clip and install new inlet seat gasket before adjusting float.
- Remove air horn gasket, invert air horn and allow float to hang by its own weight. Measure clearance between top of float and air horn. See Fig 1
.
- Clearance should be .275" (7.0 mm). Adjust clearance by bending float arm at tab "A". See Fig 2
.