FixVault

Starter - HITACHI: Specifications

STARTER NO LOAD TEST SPECIFICATIONS (1)

Application Max. Amps Min. RPM
Impulse 60 6000
P'UP & Trooper II
Gasoline 70 6000
Diesel 120 4000
(1) Applied voltage of 11.5-12 volts.
STARTER LOAD TEST SPECIFICATIONS (1)

Application Max. Amps Volts Ft. Lbs. (N.m)
Impulse, P'UP & Trooper II
Gasoline 200 9.1 3.4 (4.6)
Diesel 500 7.5 9.4 (12.7)
(1) At minimum turning speed of 1100-1200 RPM.
BRUSH SPRING TENSION SPECIFICATIONS

Application Ozs. (g)
I-Mark Diesel 96-106 (2717-3000)
All Others 56 (1585)
MINIMUM BRUSH LENGTH SPECIFICATIONS

Application In. (mm)
I-Mark & Spectrum .35 (9.0)
Impulse, P'UP & Trooper II (Gasoline) .47 (12.0)