FixVault

Tune-Up - 4-CYL: Adjustments: Distributor

All models use transistorized ignition which eliminates breaker points. Reluctor-to-pick-up air gap is the only adjustment. Measure air gap with a non-magnetic feeler gauge and move pick-up piece if necessary to correct air gap.

DISTRIBUTOR RELUCTOR-TO-PICK-UP AIR GAP

Application In. (mm)
All Models 0.008-0.016 (0.20-0.40)
Fig 1: Spectrum Firing Order and Distributor Rotation
G46345