FixVault

Ignition Timing

  1. Install timing light with adapter between No. 1 spark plug and No. 1 spark plug wire, or use inductive pick-up. Do not puncture wire. Run engine until it reaches normal operating temperature.
  2. Electronic Spark Timing (EST) must be in Bypass Mode to check ignition timing. Ground terminal "A" to "B" at Assembly Line Diagnostic Link (ALDL) connector.
  3. Place transmission in Neutral (man. trans.) or Drive (auto. trans.). Set average timing of cylinders No. 1 and No. 4 to specification. Adjust if necessary.
IGNITION TIMING SPECIFICATIONS (DEGREES BTDC @ RPM)

Application Man. Trans. Auto. Trans.
2.5L (1) 8 @ 650 (1) 8 @ 650
(1) With idle air controller (IAC) connected.